top of page

PROACTIVE ENVIRONMENTAL PRODUCTS®
ProFlow® Pseudocone™ Tubing

       Item Number                                                                  Description

MGE-1000                               3/16" ID x 3/8" OD - 100 FOOT COIL. Wall thickness 094 (3/32)
                                              Environmental grade natural color elastomer tubing. Great substitute for the MF# LS15.
                                              Used with .170" id x 1/4" od or 1/4" id x 3/8' od connection tube.
                                              Compatible with Proactive Environmental Products Peristaltic Pumps.
 

                                             

MGE-2000                               1/4" ID x 7/16" OD - 100 FOOT COIL. Wall thickness 094 (3/32)
                                               Environmental grade natural color elastomer tubing. Great substitute for the MF# LS24.
                                               Used with .170" id x 1/4" od or 1/4" id x 3/8" od downhole tube.
                                               Compatible with Proactive Environmental Products Peristaltic pumps.


MGE-3000                                3/8" ID x 5/8" OD - 100 FOOT COIL.
                                               Environmental grade natural color elastomer tubing. Great substitute for the MF# LS36.
                                               Compatible with Proactive Environmental Products Peristaltic pumps.
   

Specifications: 
All ProFlow® Pseudocone™ tubing offers the following:

  • Formulated without Cadmium, Lead, Mercury, Hexavalent Chromium, Polybrominated Biphenyls or Polybrominated Diphenyl Ethers in accordance with European restrictions and hazardous substances

  • Formulated to meet the requirements of the U.S. Pharmacopoeia Class VI Biological Tests for Plastics 

  • Meets REACH, ROHS & Proposition 65 requirements 

  • Meets ISO10993 requirements

Properties                                             ASTM Method                              Value Rating 
Hardness; Shore A (+/-5)                       D2240                                          56
Vacuum                                                                                                    Recommended 
Operating temperature range                                                                   -25 -165
Maximum Working Pressure                                                                     73o / 20PSI
Testing Size                                                                                               3/16" ID x 3/8" OD 
Color                                                                                                         Translucent 
Odor                                                                                                         Slight 
Taste                                                                                                         None
Specific Gravity; g/cm3                          D792                                            .889
Tensile Strength; psi                              D638                                            890
Ultimate Elongation; %                          D638                                           640

​Corporate Headquarters:

9040 Town Center Parkway, Suite 101

Lakewood Ranch, Florida 34202

​

Shipping and Mailing Address:

1767 Lakewood Ranch Blvd, Suite #113

Bradenton Florida 34211

​

Phone: 1.941.243.3930

Call Us Toll Free At:  (1.877.99.HYDRO)

Note: Prices on our website are in USD

|
|

Specifications change without notice

State Groundwater Sampling Procedures:

  • Alabama Groundwater Monitoring Well Sampling Procedures

  • Alaska Groundwater Monitoring Well Sampling Procedures

  • Arizona Groundwater Monitoring Well Sampling Procedures

  • Arkansas Groundwater Monitoring Well Sampling Procedures

  • California Groundwater Monitoring Well Sampling Procedures

  • Colorado Groundwater Monitoring Well Sampling Procedures

  • Connecticut Groundwater Monitoring Well Sampling Procedures

  • Delaware Groundwater Monitoring Well Sampling Procedures

  • Florida Groundwater Monitoring Well Sampling Procedures

  • Georgia Groundwater Monitoring Well Sampling Procedures

  • Hawaii Groundwater Monitoring Well Sampling Procedures

  • Idaho Groundwater Monitoring Well Sampling Procedures

  • Illinois Groundwater Monitoring Well Sampling Procedures

  • Indiana Groundwater Monitoring Well Sampling Procedures

  • Iowa Groundwater Monitoring Well Sampling Procedures

  • Kansas Groundwater Monitoring Well Sampling Procedures

  • Kentucky Groundwater Monitoring Well Sampling Procedures

  • Louisiana Groundwater Monitoring Well Sampling Procedures

  • Maine Groundwater Monitoring Well Sampling Procedures

  • Maryland Groundwater Monitoring Well Sampling Procedures

  • Massachusetts Groundwater Monitoring Well Sampling Procedures

  • Michigan Groundwater Monitoring Well Sampling Procedures

  • Minnesota Groundwater Monitoring Well Sampling Procedures

  • Mississippi Groundwater Monitoring Well Sampling Procedures

  • Missouri Groundwater Monitoring Well Sampling Procedures

  • Montana Groundwater Monitoring Well Sampling Procedures

  • Nebraska Groundwater Monitoring Well Sampling Procedures

  • Nevada Groundwater Monitoring Well Sampling Procedures

  • New Hampshire Groundwater Monitoring Well Sampling Procedures

  • New Jersey Groundwater Monitoring Well Sampling Procedures

  • New Mexico Groundwater Monitoring Well Sampling Procedures

  • New York Groundwater Monitoring Well Sampling Procedures

  • North Carolina Groundwater Monitoring Well Sampling Procedures

  • North Dakota Groundwater Monitoring Well Sampling Procedures

  • Ohio Groundwater Monitoring Well Sampling Procedures

  • Oklahoma Groundwater Monitoring Well Sampling Procedures

  • Oregon Groundwater Monitoring Well Sampling Procedures

  • Pennsylvania Groundwater Monitoring Well Sampling Procedures

  • Rhode Island Groundwater Monitoring Well Sampling Procedures

  • South Carolina Groundwater Monitoring Well Sampling Procedures

  • South Dakota Groundwater Monitoring Well Sampling Procedures

  • Tennessee Groundwater Monitoring Well Sampling Procedures

  • Texas Groundwater Monitoring Well Sampling Procedures

  • Utah Groundwater Monitoring Well Sampling Procedures

  • Vermont Groundwater Monitoring Well Sampling Procedures

  • Virginia Groundwater Monitoring Well Sampling Procedures

  • Washington Groundwater Monitoring Well Sampling Procedures

  • West Virginia Groundwater Monitoring Well Sampling Procedures

  • Wisconsin Groundwater Monitoring Well Sampling Procedures

  • Wyoming Groundwater Monitoring Well Sampling Procedures

Copyright 2021 Proactive Environmental Products LLC®. All rights Reserved.

bottom of page