BOTTOM INLET SCREEN REMOVAL TOOL
BOTTOM INLET SCREEN REMOVAL TOOL
BOTTOM INLET SCREEN REMOVAL TOOL
Item# PAPOS-14095
PROACTIVE ENVIRONMENTAL PRODUCTS®
PRO TRANSFORMER #4
Free up your Time! Free Up Your Mind!
Proactive® Smart AC to 12 Volt DC Transformer with Liquid Detection (LD) and Tank Float Switch Autonomous Pump Control Technology!
Set it and Forget it!
Weatherproof Pro Transformer #4 provides Constant Voltage Boosting Technology (CVBT)
and autonomous pump operation incorporating Liquid Detection Sensor (LD), Multiple
Settings Timer, and Tank Float Switch Technologies
The Pro Transformer #4 is compatible with the
Proactive Environmental Products® pumps listed below:
Poseidon® 100 pump
Frontier® 100 pump
If you plan to power the Proactive® brand pumps listed above with other means of energy, please contact us to discuss the full line of Proactive® Autonomous Pump Control System options for: Solar, 12 volt battery / 12 volt battery bank, or gas generator.
Applications of the Pro Transformer #4: When using the Poseidon® 100 and SS Mini Monsoon® XL 100 series pump lines include, but not limited to:
24/7 stationed applications in groundwater, surface water, vaults or the like for: Pump Tests, Long or Short Term Purge, Remediation, Liquid Transfer, Groundwater and Surface Water Monitoring
Applications of the Pro Transformer #4: When using the SS Mini Monsoon® XL 100 series pump line include, but not limited to:
24/7 stationed applications in groundwater, surface water, vaults or the like for: Pump Tests, Long or Short Term Purge, Remediation, Liquid Transfer, Groundwater and Surface Water Monitoring, Hydrocarbon Recovery [LNAPL/DNAPL]
Applications of the Pro Transformer #4: When using the Frontier® 100 series pump line:
Stationed application for cabin use
Pro Transformer #4 provides flexible product features. If you appreciate options (the good news all options are included with the product), you will be pleased to know you can select from any or all of the Pro Transformer #4 features!
Option #1: LD Sensor Detection and Dry Run Detection Feature
The LD sensor detects (conductive) liquid*. The pump will run as long as the LD sensor is suspended in liquid. When liquid draws down below the LD sensor, the dry run sensor takes over and transmits a signal to the Pro Transformer #4 to shut-off the pump. As liquid level rises again covering the LD sensor, the LD sensor takes over and transmits a signal to the Pro Transformer #4 to turn-on the pump. This cycle continues automatically.
Option #2: Tank Float Switch Feature
This feature prevents tank over-fill and provides control over the desired total volume of liquid that enters the tank. The tank float switch detects the full-set point (assigned upon tank float switch deployment) and transmits a signal to the Pro Transformer #4 to shut-off the pump. The pump remains off until the tank reservoir drops triggering the tank float switch to transmit a signal to the Pro Transformer #4 to turn-on the pump again. This cycle continues automatically.
Option #3: Multiple Settings Timer
The Pro Transformer #4 timer provides multiple (up to 19 on/off interval) time settings within a 24 hour period delivering total autonomous pump run-time control. This cycle continues automatically.
Option#4: Incorporate all Autonomous Features
The LD and Dry Run Detection Sensors, Tank Float Sensor Switch and Multiple Settings Timer proving the ultimate experience in autonomous pump control system available!
Pro Transformer #4
The Ultimate Pump Control With Liquid Detection Sensor Technology
Configure The Pro Transformer #4 The Way You Want It!
Benefits:
-
The most economical and simple solution to autonomous pump control
-
Provides Peace of Mind with autonomous pump control so you don't have to
-
Improves time management! Literally set the Pro Transformer #4 and autonomous settings with pump and forget it
-
Save money! Eliminate archaic, bulky, and expensive equipment
-
User-friendly install takes roughly 30-45 minutes to setup (not including the cable run for the LD and Dry Run Sensors)
-
User-friendly and easy access controls
-
Ideal for all AC powered sites, including remote sites
-
Look like a PRO when your clients see how much money you save them by deploying Proactive® AC to 12 volt DC Autonomous Pump Control Technology
Features:
-
Diverse: Engineered to be used with Proactive® 100 series pump lines
-
Option to select either 110 or 220 AC volt with easy-access slide switch
-
One time setup
-
Consistent amp output for consistent flow
-
Constant Voltage Boosting Technology (CVBT) allows the correct voltage to reach the pump motors for consistent flow
-
Same pump settings upon restart every on/off cycle or from power outage
-
Flexibility to choose the options that will get the job done accurately, faster, and under budget
-
Lightweight and easy to mount
-
Smart temperature sensor auto shut-off at 155⁰ Fahrenheit
-
Smart temperature sensor auto turn-on when cooling period is complete
-
Designed for the outdoors incorporating a weatherproof enclosure
-
Tamper-Proof lock provides peace-of-mind
-
Warranty: Manufacturer 6 months parts and labor warranty
INTERNAL FUSE #1
AC/DC TRANSFORMER
BREAKER
TIMER
PRO LD WITH BOOSTER
DRY
SENSOR PROBE
LIQUID DETECTION SENSOR PROBE
EXTERNAL FLOAT
SMALL VENTED
TRANSFORMER
GFCI
INTERNAL FUSE #2
Pro Transformer #4 comes with:
-
Weatherproof enclosure that provides long life and protection to the components
-
AC/DC 12 volt Transformer
-
Built-in Booster
-
Built-in Multiple Settings Timer
-
Built-in 30 amp breaker
-
Liquid Detection Sensor and Dry Run Sensor probes come with:
○ 150 feet of wire per sensor spooled onto reel for: 100 Series pump lines
-
Tank Float Switch comes with 3 feet of wire (additional wire can be purchased upon request)
-
Tamper-Proof lock
-
Mounting Brackets
-
GFCI Plug
Specifications:
DC VOLT RECOMMENDATION: 12-15V
AMP CONSUMPTION (MAX): 25 AMPS
DEPTH MEASUREMENT: 8"
WIDTH MEASUREMENT: 17"
HEIGHT MEASUREMENT: 21"
WEIGHT: 19 POUNDS
INTERNAL FUSE: 25 AMP
BREAKER: 30 amp
ENCLOSURE RATED: WEATHERPROOF
Note: Product dimensions are inclusive of the Pro Transformer #4 NOT inclusive of the sensors, reels, or tank float switch.
* Liquid must contain minerals in order to use the LD sensor